Home > Products > Limit Switch > TZ-6 Aluminium Alloy Sealed Limit Switch

TZ-6001 stainless steel pin plunger Sealed Limit Switch

■ TM General-purpose Basic Switches are built into TZ-6 Switches. They provided high durability and high breaking capacity.

■ X Basic Switches with magnetic blowout are built into TZ-6 Switches. DC models have also been added to the series.

■ Three mounting methods (side, base, and diagonal side) and many types of actuator are available.

■ Terminals face the front when the cover is removed for easy connection.

■ Switches with ground terminals have CE marking.

■ Contact Form:

TZ-6001 Sealed Limit Switch

Product List

Technical Parameters

TZ-6001 Sealed Limit Switch


Ratings

ModelRated voltageNoninductive Load (A)Inductive Load (A)
Resistance LoadLamp LoadInductive LoadMotor Load
NCNONCNONCNONCNO
TZ-□AC125V1531.51552.5
AC250V152.51.241531.5
AC480V101.50.7561.50.75
DC125V0.50.50.050.05
DC250V0.250.250.030.03
TX-□DC8V1031.5101052.5
DC14V1031.5101052.5
DC30V1031.5101052.5
DC125V1031.57.5622.5
DC250V31.50.7521.521.5
Surge currentNC30A (under)
NO15A (under)


NOTES:1. The above figures are for standard currents.

2. Inductive loads have a power factor of 0.4 min.(AC) and a time constant of 7 ms max.

(DC).

3. Lamp load has an inrush current of 10 timesthe steadystate current.

4. Motor load has an inrush current of 6 times thesteady-state current.


Characteristics

Degree of protectionIP60
Allowable operating speedPush plunger type: 0.01mm/s~0.5m/s
lever type: 0.02mm/s~0.5m/s
Allowable operating frequencyElectical20times/min
Rated frequency50/60Hz
Insulation resistance100MΩ以下(DC500V时)   Under 100MΩ(DC500V)
Insulation strengthBetween homopolar terminalsAC1,000V,50/60Hz,1min
Live metal part and ground leadAC2,000V,50/60Hz,1min

Between terminals and uncharged 

metal parts

AC2,000V,50/60Hz,1min
VibrationMis-operation10~55Hz,1.5mm double-amplitude
Shockbreakdownunder 1,000m/s
Mis-operationUnder 100m/s2 (plunger &lever type), 50m/s2 (roller type)
Ambient Temp-10℃~+80℃(no ice)
Ambient humidityNormal type: 35%~85%RH
Sealed type: 35~95%RH
Weight260~280g
Electrical lifeAbove 500000


Operating Characteristics

Operating CharacteristicsModelTZ-6001TZ-6002TZ-6003TZ-6004TZ-6101TZ-6102TZ-6103TZ-6104TZ-6143
Operating forceOF(Max)2.45~3.43N2.45~3.43N2.45~3.43N5.59N以下7.85N4.90N4.90N6.28N6.28N
Release forceRF (Min)1.12N1.12N1.12N1.67N2.35N0.98N0.98N2.26N2.26N
Pre-travelPT  (Max)0.4mm0.5mm0.5mm4mm2mm1mm1mm5mm5mm
Over-travelOT  (Min)5.5mm3.6mm3.6mm6mm5mm3.5mm3.5mm6mm6mm
Movement differentialMD (Max)0.05mm0.05mm0.05mm0.47mm0.1mm0.12mm0.12mm0.4mm0.4mm
Operational positionOP38.2±0.8mm49.7±1mm49.7±1mm一45.8±1mm49.7±0.8mm49.7±0.8mm一一